Appendix1 OPERATION PROCESSING TIME
Appendix 1.2 Operation Processing Time of Basic Model QCPU
Instruction Condition (Device)
Processing Time (µs)
Q00JCPU Q00CPU Q01CPU
ORD < >
When not executed 0.80 0.64 0.40
When executed
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
LDD >
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
ANDD >
When not executed 0.80 0.64 0.40
When executed
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
ORD >
When not executed 0.80 0.64 0.40
When executed
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
LDD < =
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
ANDD < =
When not executed 0.80 0.64 0.40
When executed
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
ORD < =
When not executed 0.80 0.64 0.40
When executed
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
LDD <
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
ANDD <
When not executed 0.80 0.64 0.40
When executed
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
ORD <
When not executed 0.80 0.64 0.40
When executed
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
LDD > =
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
ANDD > =
When not executed 0.80 0.64 0.40
When executed
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
ORD > =
When not executed 0.80 0.64 0.40
When executed
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
BKCMP = n
n = 1 130 105 97
BKCMP = P n
n = 96 205 175 165
BKCMP<> n
n = 1 130 105 98
BKCMP<>P n
n = 96 210 180 165
BKCMP> n
n = 1 130 105 97
BKCMP>P n
n = 96 210 180 165
BKCMP>= n
n = 1 130 105 98
BKCMP>=P n
n = 96 205 175 165
S1
S2
D
S1
S2
D
S1
S2
D
S1
S2
D
S1
S2
D
S1
S2
D
S1
S2
D
S1
S2
D