Appendix1 OPERATION PROCESSING TIME
Appendix 1.4 Operation Processing Time of Universal Model QCPU
Category Instruction Condition (Device)
Processing Time (µs)
Q00UJCPU Q00UCPU
Q01UCPU Q02UCPU
Min. Max. Min. Max. Min. Max. Min. Max.
Application
instruction
ANDDT<>
When not executed
0.480 0.320 0.240 0.160
Comparison
of specified
date
In conductive
status
8.200 25.500 8.200 25.500 6.500 25.500 7.200 23.400
In nonconductive
status
8.200 25.500 8.200 25.500 6.500 25.500 7.200 23.400
Comparison
of current
date
In conductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.200
In nonconductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.200
ORDT<>
When not executed
0.480 0.320 0.240 0.160
Comparison
of specified
date
In conductive
status
8.200 25.500 8.200 25.500 6.500 25.500 7.400 23.300
In nonconductive
status
8.200 25.500 8.200 25.500 6.500 25.500 7.400 23.300
Comparison
of current
date
In conductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.000
In nonconductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.000
LDDT>
Comparison
of specified
date
In conductive
status
8.200 25.500 8.200 25.500 6.500 25.500 7.400 23.400
In nonconductive
status
8.200 25.500 8.200 25.500 6.500 25.500 7.400 23.400
Comparison
of current
date
In conductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.200
In nonconductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.200
ANDDT>
When not executed
0.480 0.320 0.240 0.160
Comparison
of specified
date
In conductive
status
8.200 25.500 8.200 25.500 8.200 25.500 7.200 23.400
In nonconductive
status
8.200 25.500 8.200 25.500 8.200 25.500 7.200 23.400
Comparison
of current
date
In conductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.200
In nonconductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.200
ORDT>
When not executed
0.480 0.320 0.240 0.160
Comparison
of specified
date
In conductive
status
8.200 25.500 8.200 25.500 8.200 25.500 7.400 23.300
In nonconductive
status
8.200 25.500 8.200 25.500 8.200 25.500 7.400 23.300
Comparison
of current
date
In conductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.000
In nonconductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.000
LDDT<=
Comparison
of specified
date
In conductive
status
8.200 25.500 8.200 25.500 6.500 25.500 7.400 23.400
In nonconductive
status
8.200 25.500 8.200 25.500 6.500 25.500 7.400 23.400
Comparison
of current
date
In conductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.200
In nonconductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.200