Mitsubishi Electronics QSERIES Smoker User Manual


  Open as PDF
of 1204
 
12-50
3401
[REMOTE PASS. ERR.]
Position specified as the head I/O number of the
remote password file is incorrect due to one of the
following reasons:
• Module is not loaded.
• Other than a the intelligent function module (I/O
module)
• Intelligent function module other than serial
communication module, modem interface
module or Ethernet module
• Serial communication module or Ethernet
module of function version A
The intelligent function module where remote
password is available is not mounted.
Collateral information
• Common Information:–
• Individual Information:–
Diagnostic Timing
• At power ON/At reset/STOP RUN
Mount serial communication module, modem
interface module or Ethernet module of function
version B or later in the position specified in the
head I/O No. of the remote password file.
RUN:
Off
ERR.:
Flicker
CPU Status:
Stop
Qn(H)
*1
QnPH
QnPRH
QnU
[REMOTE PASS. ERR.]
Any of the following modules is not mounted on the
slot specified for the head I/O number of the remote
password.
• Serial communication module of function version
B or later
• Ethernet module of function version B or later
• Modem interface module of function version B or
later
Collateral information
• Common Information:–
• Individual Information:–
Diagnostic Timing
• At power ON/At reset/STOP RUN
Mount any of the following modules in the position
specified for the head I/O number of the remote
password.
• Serial communication module of function version
B or later
• Ethernet module of function version B or later
• Modem interface module of function version B or
later
Q00J/Q00/Q01
*1
[REMOTE PASS. ERR.]
Serial communication module, modem interface
module or Ethernet module of function version B or
later controlled by another CPU was specified in a
multiple CPU system.
Collateral information
• Common Information:–
• Individual Information:–
Diagnostic Timing
• At power ON/At reset/STOP RUN
• Change it for the Ethernet module of function
version B or later connected by the host CPU.
• Delete the remote password setting.
Qn(H)
*1
QnPH
QnU
*10
Error
Code
(SD0)
Error Contents and Cause Corrective Action
LED Status
CPU Status
Corresponding
CPU
*1 The function version is B or later.
*10 The Universal model QCPU except the Q00UJCPU.