Mitsubishi Electronics QSERIES Smoker User Manual


  Open as PDF
of 1204
 
App-80
Category Instruction Condition (Device)
Processing Time (µs)
Q00UJCPU Q00UCPU
Q01UCPU Q02UCPU
Min. Max. Min. Max. Min. Max. Min. Max.
Application
instruction
RSET
Standard RAM
6.800 26.900 6.800 26.900 6.800 26.900 3.000 16.400
SRAM card
–– –– –– –– –– –– 3.000 16.400
QDRSET
SRAM card to standard RAM
–– –– –– –– –– –– 230.000 327.000
Standard RAM to SRAM card
–– –– –– –– –– –– 997.000 1066.000
QCDSET
SRAM card to standard ROM
–– –– –– –– –– –– 525.000 690.000
Standard ROM to SRAM card
–– –– –– –– –– –– 490.000 655.000
DATERD
–– 5.600 27.800 5.600 27.800 5.600 27.800 5.100 14.700
DATEWR
–– 7.800 42.100 7.800 42.100 7.800 42.100 7.100 23.000
DATE +
No digit increase
14.200 41.200 14.200 41.200 14.200 41.200 6.500 13.100
Digit increase
14.200 41.200 14.200 41.200 14.200 41.200 5.700 21.200
DATE -
No digit increase
15.100 41.200 15.100 41.200 15.100 41.200 6.500 11.500
Digit increase
15.100 41.200 15.100 41.200 15.100 41.200 5.700 17.200
SECOND
–– 5.800 20.500 5.800 20.500 5.800 20.500 2.600 5.900
HOUR
–– 6.200 22.500 6.200 22.500 6.200 22.500 3.000 5.300
LDDT =
Comparison
of specified
date
In conductive
status
8.200 25.500 8.200 25.500 6.500 25.500 7.400 23.400
In nonconductive
status
8.200 25.500 8.200 25.500 6.500 25.500 8.200 25.500
Comparison
of current
date
In conductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.200
In nonconductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.200
ANDDT=
When not executed
0.480 0.320 0.240 0.160
Comparison
of specified
date
In conductive
status
8.200 25.500 8.200 25.500 6.500 25.500 7.200 23.400
In nonconductive
status
8.200 25.500 8.200 25.500 6.500 25.500 7.200 23.400
Comparison
of current
date
In conductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.200
In nonconductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.200
ORDT=
When not executed
0.480 0.320 0.240 0.160
Comparison
of specified
date
In conductive
status
8.200 25.500 8.200 25.500 6.500 25.500 7.400 23.300
In nonconductive
status
8.200 25.500 8.200 25.500 6.500 25.500 7.400 23.300
Comparison
of current
date
In conductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.000
In nonconductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.000
LDDT <>
Comparison
of specified
date
In conductive
status
8.200 25.500 8.200 25.500 6.500 25.500 7.400 23.400
In nonconductive
status
8.200 25.500 8.200 25.500 6.500 25.500 7.400 23.400
Comparison
of current
date
In conductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.200
In nonconductive
status
6.500 23.100 6.500 23.100 6.500 23.100 5.900 22.200