Mitsubishi Electronics QSERIES Smoker User Manual


  Open as PDF
of 1204
 
12-22
2110
[SP. UNIT ERROR]
• The location designated by the FROM/TO
instruction set is not the intelligent function
module/special function module.
• The module that does not include buffer memory
has been specified by the FROM/TO instruction.
• The intelligent function module/special function
module, Network module being accessed is
faulty.
• Station not loaded was specified using the
instruction whose target was the CPU share
memory.
Collateral information
• Common Information:Module No. (Slot No.)
• Individual Information:Program error location
Diagnostic Timing
• When instruction executed
• Read the individual information of the error using
the GX Developer, check the FROM/TO
instruction that corresponds to that numerical
value (program error location), and correct when
necessary.
• The intelligent function module/special function
module that was accessed is experiencing a
hardware fault. Therefore, change the faulty
module. Alternatively, contact your local
Mitsubishi representative.
RUN:
Off/On
ERR.:
Flicker/On
CPU Status:
Stop/
Continue
*1
Q00J/Q00/Q01
Qn(H)
*3
QnPH
QnPRH
QnU
2111
[SP. UNIT ERROR]
• The location designated by a link direct device
(J \ ) is not a network module.
• The I/O module (intelligent function module/
special function module) was nearly removed,
completely removed, or mounted during running.
Collateral information
• Common Information:Module No. (Slot No.)
• Individual Information:Program error location
Diagnostic Timing
• When instruction executed
QCPU
2112
[SP. UNIT ERROR]
• The module other than intelligent function
module/special function module is specified by
the intelligent function module/special function
module dedicated instruction.
Or, it is not the corresponding intelligent function
module/special function module.
• There is no network No. specified by the network
dedicated instruction.
Or the relay target network does not exit.
Collateral information
• Common Information:Module No. (Slot No.)
• Individual Information:Program error location
Diagnostic Timing
• When instruction executed/STOP RUN
Read the individual information of the error using a
peripheral device, and check the special function
module /special function module dedicated
instruction (network instruction) that corresponds to
the value (program error part) to make modification.
2113
[SP. UNIT ERROR]
The module other than network module is specified
bythe network dedicated instruction.
Collateral information
• Common Information:FFFF
H (fixed)
• Individual Information:Program error location
Diagnostic Timing
• When instruction executed/STOP RUN
Qn(H)
QnPH
Error
Code
(SD0)
Error Contents and Cause Corrective Action
LED Status
CPU Status
Corresponding
CPU
*1 CPU operation can be set in the parameters at error occurrence. (LED indication varies.)
*3 The function version is B or later.