Mitsubishi Electronics QSERIES Smoker User Manual


  Open as PDF
of 1204
 
App-88
Remark
For the instructions for which a rise execution instruction ( P) is not specified,
the processing time is the same as an ON execution instruction.
WORDP instruction and TOP instruction
Category Instruction Condition (Device)
Processing Time (µs)
Q00UJCPU Q00UCPU
Q01UCPU Q02UCPU
Min. Max. Min. Max. Min. Max. Min. Max.
Multiple
CPU
dedicated
instruction
S.TO n1 n2 n3 n4
Writing to host
CPU shared
memory
n4 = 1
64.600 78.100 64.600 78.100 64.600 78.100 64.600 78.100
n4 = 320
115.000 126.000 115.000 126.000 115.000 126.000 154.000 126.000
TO n1 n2 n3
Writing to host
CPU shared
memory
n3 = 1
12.700 62.200 12.700 62.200 12.700 62.200 8.300 58.200
n3 = 320
63.500 112.300 63.500 112.300 63.500 112.300 56.200 107.800
DTO n1 n2 n3
Writing to host
CPU shared
memory
n3 = 1
13.500 62.300 13.500 62.300 13.500 62.300 8.600 58.300
n3 = 320
112.900 160.800 112.900 160.800 112.900 160.800 106.800 157.300
FROM n1 n2 n3
Reading from
host CPU shared
memory
n3 = 1
12.100 58.700 12.100 58.700 12.100 58.700 8.400 52.600
n3 = 320
56.000 101.700 56.000 101.700 56.000 101.700 51.700 96.600
Reading from
other CPU
shared memory
n3 = 1
24.400 82.900 24.400 82.900 24.400 82.900 16.600 37.000
n3 = 320
152.000 243.000 152.000 243.000 152.000 243.000 153.000 185.000
n3 = 1000
418.000 518.000 418.000 518.000 418.000 518.000 432.000 485.000
DFRO n1 n2 n3
Reading from
host CPU shared
memory
n3 = 1
12.100 58.700 12.100 58.700 12.100 58.700 8.800 53.400
n3 = 320
97.400 143.700 97.400 143.700 97.400 143.700 94.900 139.600
Reading from
other CPU
shared memory
n3 = 1
24.800 94.200 24.800 94.200 24.800 94.200 16.600 47.300
n3 = 320
276.000 367.000 276.000 367.000 276.000 367.000 278.000 339.000
n3 = 1000
799.000 892.000 799.000 892.000 799.000 892.000 841.000 892.000
D
S
S
D
D
Example