TableApp.4.8 Special register
Number Name Meaning Explanation
Set by
(When Set)
Corres-
ponding
ACPU
D9
Corresponding
CPU
SD774
to
SD775
PID limit setting
(for complete
derivative)
0: With limit
1: Without limit
Specify the limit of each PID loop as shown below.
UNew
Qn(H)
QnPRH
QnU
SD774
PID limit setting
(for complete
derivative)
0: With limit
1: Without limit
Specify the limit of each PID loop as shown below.
UNew
Q00J/Q00/Q01
*9
SD778
Refresh
processing
selection when
the COM/
CCOM
instruction is
executed
b0 to b14:
0: Do not
refresh
1: Refresh
b15 bit
0: Communication
with CPU
module is
executed
1: Communication
withCPU
module is
nonexecuted
Selects whether or not the data is refreshed when the COM instruction is
executed.
Designation of SD778 is made valid when SM775 turns ON.
Refresh between multiple CPUs by COM instruction is performed under
the following occasion.
Receiving operation from other device: b4 of SD778(refresh in the CPU
shared memory) is turned to 1.
Sending operation from host CPU : b15 of SD778(communication with
peripheral device is executed/nonexecuted) is turned to 0.
UNew
Q00J/Q00/Q01
*9
Qn(H)
*11
Selects whether or not the data is refreshed when the COM instruction is
executed.
Designation of SD778 is made valid when SM775 turns ON.
Refresh between multiple CPUs by COM instruction is performed under
the following occasion.
Receiving operation from other device: b4 of SD778(refresh in the CPU
shared memory) is turned to 1.
Sending operation from host CPU : b15 of SD778(communication with
peripheral device is executed/nonexecuted) is turned to 0.
When b2 (refresh of the CC-Link IE controller network and
MELSECNET/H) of SD778 is 1, the CC-Link IE controller network and
MELSECNET/H perform refresh.
Therefore, if there are many refresh points, processing time for the COM
instruction will be extended.
UNew
Qn(H)
*13
QnPH
*12
QnPRH
SD774
SD775
b15
to
to
Loop2
Loop18
Loop1
Loop17
b1 b0
Loop16
Loop32
SD774
b15
to
toto
b1 b0b7b8
Loop8 Loop2 Loop1
b0b1b2b3b4b5b14b15
0
to
I/O refresh
CC-Link refresh
MELSECNET/H
refresh
Automatic refresh of
intelligent function
modules
Execution/non-
execution of
communication with
CPU module
Automatic refresh of
CPU shared memory
(Fixed to "0" for
Redundant CPU)
0/10/10/10/10/10/1
SD778
b0b1b2b3b4b5b6b14b15
0
to
I/O refresh
CC-Link refresh
CC-Link IE controller
network or
0/10/10/10/10/10/10/1
SD778
Automatic refresh of
intelligent function
modules
Execution/non-
execution of
communication with
CPU module
Reading input/output
from group outside
multiple CPU system
Auto refresh using the
multiple CPU high speed
transmission area of
multiple CPU system
MELSECNET/H refresh