6
7
8
Appendix1 OPERATION PROCESSING TIME
Appendix 1.4 Operation Processing Time of Universal Model QCPU
Category Instruction Condition (Device)
Processing Time (µs)
Q00UJCPU Q00UCPU
Q01UCPU
Q02UCPU
Min. Max. Min. Max. Min. Max. Min. Max.
Basic
instruction
LDED<
Double
precision
In conductive status
4.700 37.400 4.700 37.400 4.700 37.400 5.100 25.000
In non-conductive status
4.700 37.400 4.700 37.400 4.700 37.400 4.200 24.100
ANDED<
Double
precision
When not executed
0.360 0.240 0.180 0.120
When
executed
In conductive status
4.500 34.700 4.500 34.700 4.500 34.700 4.000 19.400
In non-conductive status
4.500 34.700 4.500 34.700 4.500 34.700 4.100 19.700
ORED<
Double
precision
When not executed
0.360 0.240 0.180 0.120
When
executed
In conductive status
4.700 33.200 4.700 33.200 4.700 33.200 5.000 25.100
In non-conductive status
4.700 33.200 4.700 33.200 4.700 33.200 5.000 25.100
LDED>=
Double
precision
In conductive status
4.700 37.400 4.700 37.400 4.700 37.400 4.200 13.100
In non-conductive status
4.700 37.400 4.700 37.400 4.700 37.400 4.300 13.100
ANDED>=
Double
precision
When not executed
0.360 0.240 0.180 0.120
When
executed
In conductive status
4.500 34.700 4.500 34.700 4.500 34.700 3.900 19.500
In non-conductive status
4.500 34.700 4.500 34.700 4.500 34.700 4.100 19.800
ORED>=
Double
precision
When not executed
0.360 0.240 0.180 0.120
When
executed
In conductive status
4.700 33.200 4.700 33.200 4.700 33.200 5.000 25.100
In non-conductive status
4.700 33.200 4.700 33.200 4.700 33.200 4.200 18.500
LD$=
In conductive status
8.300 38.500 8.300 38.500 8.300 38.500 5.500 14.900
In non-conductive status
8.300 38.500 8.300 38.500 8.300 38.500 5.500 15.600
AND$=
When not executed
0.360 0.240 0.180 0.120
When executed
In conductive status
7.200 37.300 7.200 37.300 7.200 37.300 5.200 13.800
In non-conductive status
7.200 37.300 7.200 37.300 7.200 37.300 5.300 14.500
OR$=
When not executed
0.360 0.240 0.180 0.120
When executed
In conductive status
7.500 36.600 7.500 36.600 7.500 36.600 5.500 14.900
In non-conductive status
7.500 36.600 7.500 36.600 7.500 36.600 5.300 14.600
LD$< >
In conductive status
8.300 39.300 8.300 39.300 8.300 39.300 5.600 15.200
In non-conductive status
8.300 39.300 8.300 39.300 8.300 39.300 5.600 15.400
AND$< >
When not executed
0.360 0.240 0.180 0.120
When executed
In conductive status
8.000 38.200 8.000 38.200 8.000 38.200 4.300 21.500
In non-conductive status
8.000 38.200 8.000 38.200 8.000 38.200 4.500 23.400
OR$< >
When not executed
0.360 0.240 0.180 0.120
When executed
In conductive status
8.300 37.300 8.300 37.300 8.300 37.300 5.400 17.700
In non-conductive status
8.300 37.300 8.300 37.300 8.300 37.300 5.300 19.400
LD$>
In conductive status
8.300 41.600 8.300 41.600 8.300 41.600 6.400 19.200
In non-conductive status
8.300 41.600 8.300 41.600 8.300 41.600 5.600 20.100
AND$>
When not executed
0.360 0.240 0.180 0.120
When executed
In conductive status
8.000 38.100 8.000 38.100 8.000 38.100 4.500 15.400
In non-conductive status
8.000 38.100 8.000 38.100 8.000 38.100 4.600 15.300
OR$>
When not executed
0.360 0.240 0.180 0.120
When executed
In conductive status
8.200 35.700 8.200 35.700 8.200 35.700 5.400 20.000
In non-conductive status
8.200 35.700 8.200 35.700 8.200 35.700 5.400 22.100
LD$<=
In conductive status
8.300 39.200 8.300 39.200 8.300 39.200 5.800 12.800
In non-conductive status
8.300 39.200 8.300 39.200 8.300 39.200 6.300 13.900
AND$<=
When not executed
0.360 0.240 0.180 0.120
When executed
In conductive status
7.100 36.500 7.100 36.500 7.100 36.500 6.000 16.000
In non-conductive status
7.100 36.500 7.100 36.500 7.100 36.500 6.100 16.200