Mitsubishi Electronics QSERIES Smoker User Manual


  Open as PDF
of 1204
 
7-100
WSUM(P)
Program Example
(1) The following program adds the 16-bit BIN data from D10 to D14, and stores it in D100 and
D101 when X1C is turned ON.
[Ladder Mode] [List Mode]
[Operation]
Step
Instruction
Device
4500 (BIN)
D10
2500 (BIN)
3276 (BIN)
6780 (BIN)
14948 (BIN)
D11
D12
D13
D101,D100
4444 (BIN)
D14