SQR(P)
Operation Error
(1) In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and
an error code is stored into SD0.
The value designated by is a negative number. (Error code: 4100)
The contents of the designated device or the result of the addition are not "0", or not within
the following range(For the Universal model QCPU only): (Error code: 4140)
0, 2
-126
| Contents of designated device | < 2
128
The value of the specified device is 0.
*3
(For the Basic model QCPU, High Performance model QCPU, Process CPU, Redundant
CPU, and Q4ARCPU) (Error code: 4100)
*3: There are CPU modules that will not result in an operation error if 0 is specified. For details, refer to 3.2.4.
The result exceeds the following range (Operation results in an overflow)
(For the Universal model QCPU only)
2
128
| Operation result | (Error code: 4141)
The value of the specified device is 0, unnormalized number, nonnumeric, and ± .
(For the Universal model QCPU only) (Error code: 4140)
Program Example
(1) The following program seeks the square root of the value set by the 4 BCD digits from X20
to X2F, and stores the result as a 32-bit floating decimal point type real number at D0 and
D1.
[Ladder Mode]
[List Mode]
[Operations involved when value designated by X20 to X2F is 650]
S
Inputs data used for
square root operation ( )
Converts the input data into a
32-bit floating-point real number ( )
Executes square root
operation ( )
1
2
3
Step Instruction Device
X2F
BCD value
0
D20
650
X20
Conversion
to BIN
BIN
b15
b0
BIN value
650
Conversion to
floating-point
FLT
SQR operation
D11 D10
SQR
D1 D0
650 25
.
4 951
1
2
3