Mitsubishi Electronics QSERIES Smoker User Manual


  Open as PDF
of 1204
 
12-82
9010
[<CHK>ERR ***-***]
Error detected by the CHK instruction.
Collateral information
• Common Information:Program error location
• Individual Information:Failure No.
Diagnostic Timing
• When instruction executed
Read the individual information of the error using
the peripheral device, and check the program
corresponding to the numerical value (error
number) there.
RUN:
On
ERR.:
Off
USER LED On
CPU Status:
Continue
Qn(H)
QnPH
QnPRH
9020
[BOOT OK]
Storage of data onto ROM was completed normally
in automatic write to standard ROM.
(BOOT LED also flickers.)
Collateral information
• Common Information:–
• Individual Information:–
Diagnostic Timing
• At power ON/At reset
Use the DIP switches to set the valid parameter
drive to the standard ROM. Then, switch power on
again, and perform boot operation from the
standard ROM.
RUN:
Off
ERR.:
Flicker
CPU Status:
Stop
Qn(H)
*1
QnPH
QnPRH
10000
[CONT. UNIT ERROR]
In the multiple CPU system, an error occurred in
the CPU module other than the Process CPU/High
Performance model QCPU.
Collateral information
• Common Information:–
• Individual Information:–
Diagnostic Timing
• Always
Check the details of the generated error by
connecting to the corresponding CPU module
using GX Developer.
RUN:
Off
ERR.:
Flicker
CPU Status:
Continue
Qn(H)
*1
QnPH
Error
Code
(SD0)
Error Contents and Cause Corrective Action
LED Status
CPU Status
Corresponding
CPU
*1 The function version is B or later.