Mitsubishi Electronics QSERIES Smoker User Manual


  Open as PDF
of 1204
 
7-291
EXP(P)
1
2
3
4
6
6
7
8
7.12 Special function instructions
7.12.21 Exponent operation on floating-point data (Single precision) (EXP(P))
7.12.21 Exponent operation on floating-point data
(Single precision) (EXP(P))
EXP(P)
*2: Applicable for the Universal model QCPU only.
Function
(1) Returns the exponent of the value designated by , and stores the results of the operation
at the device designated by .
(2) Exponent operations are calculated taking the base (e) to be "2.71828".
Basic model QCPU: The upper five digits of the serial No. are "04122" or larger.
: Data of which the exponential value is obtained or head number of the devices where the data is stored
(real number)
: Head number of the devices where the operation result will be stored (real number)
Setting
Data
Internal Devices
R, ZR
J\
U\G
Zn
Constants
E
Other
Bit Word Bit Word
–– ––
*2
––
–– ––
*2
–– ––
Process
High
performance
Redundant
Universal
Ver.
Basic
Command
Command
EXPP
EXP
EXPP
EXP S D
S D
S
D
S
D
S
D
32-bit floating-point
real number
(
)
32-bit floating-point
real number
e
+1 +1
S DS D