Mitsubishi Electronics QSERIES Smoker User Manual


  Open as PDF
of 1204
 
12-48
3202
[SFC PARA. ERROR]
The number of step relays specified in the device
setting of the PLC parameter dialog box is less than
that used in the program.
Collateral information
• Common Information:File name
• Individual Information:Parameter number
Diagnostic Timing
• STOP RUN
Read the common information of the error using
the peripheral device, check error step
corresponding to its numerical value (program error
location), and correct the problem.
RUN:
Off
ERR.:
Flicker
CPU Status:
Stop
Qn(H)
QnPH
QnPRH
3203
[SFC PARA. ERROR]
The execution type of the SFC program specified in
the program setting of the PLC parameter dialog
box is other than scan execution.
Collateral information
• Common Information:File name
• Individual Information:Parameter number
Diagnostic Timing
• At power-ON/ At reset/ STOP RUN
*3
Qn(H)
QnPH
QnPRH
QnU
3300
[SP. PARA ERROR]
The start I/O number in the intelligent function
module parameter set on GX Configurator differs
from the actual I/O number.
Collateral information
• Common Information:File name
• Individual Information:Parameter number
*2
Diagnostic Timing
• At power-On/ At reset/ STOP RUN/
At writing to progurammable controller
Check the parameter setting. QCPU
3301
[SP. PARA ERROR]
• The refresh setting of the intelligent function
module exceeded the file register capacity.
• The intelligent function module set in GX
Configurator differs from the actually mounted
module.
Collateral information
• Common Information:File name
• Individual Information:Parameter number
*2
Diagnostic Timing
• At power-On/ At reset/ STOP RUN/
At writing to progurammable controller
• Change the file register file for the one which
allows refresh in the whole range.
• Check the parameter setting.
Q00J/Q00/Q01
Qn(H)
*1
QnPH
QnPRH
QnU
[SP. PARA ERROR]
The intelligent function module's refresh parameter
setting is outside the available range.
Collateral information
• Common Information:File name
• Individual Information:Parameter number
*2
Diagnostic Timing
• At power-On/ At reset/ STOP RUN/
At writing to progurammable controller
Check the parameter setting. QCPU
[SP. PARA ERROR]
The setting of the refresh parameter range crosses
over the boundary between the internal user device
and the extended data register (D) or extended link
register (W).
Collateral information
• Common Information:File name
• Individual Information:Parameter number
*2
Diagnostic Timing
• At power-On/ At reset/ STOP RUN/
At writing to progurammable controller
Set the refresh parameter range so that it does not
cross over the boundary between the internal user
device and the extended data register (D) or
extended link register (W).
QnU
Error
Code
(SD0)
Error Contents and Cause Corrective Action
LED Status
CPU Status
Corresponding
CPU
*1 The function version is B or later.
*2 Parameter No. is the value gained by dividing the head I/O number of parameter in the intelligent function module set by GX Configurator by 10H.
*3 The diagnostic timing of CPU modules except for Universal QCPU can be performed only when switching the CPU modules to run.