3D Innovations DLT8000 Gas Grill User Manual


 
7DQGEHUJ'/73URGXFW0DQXDO $
A. Definition of Vendor Unique
Sense Data Information
7KLVDSSHQGL[OLVWVWKHLQWHUQDOVWDWXVFRGHVZLWKWKHLUGHVFULSWLRQV
The internal status code is located at byte offset 18 of the REQUEST SENSE data
and may be available for certain types of failures.
127(
Byte 18 of the REQUEST SENSE data has two formats: a byte code and
a bit flags format. The bit flags format is used when there is no internal
status code to report and can be quickly distinguished by checking to see
if bit 7 of byte 18 is set to 1.
'HFLPDO
+H[DGHFLPDO
'HVFULSWLRQ
0 0 No Meaning
1 1 Reed-Solomon Error Correction Code Recovery
2 2 READ or WRITE Block Retry (Soft Retry)
3 3 REPOSITION Command Aborted
4 4 Controller Has Stopped Reading
5 5 No Control or Data Buffers Available
6 6 Target Delivered in Read Ahead
7 7 Logical EOT Encountered, 2 Filemarks
8 8 Command Connection Dropped
9 9 Cleared from Queue
10 0A Missing Data Block – READ only
11 0B Gap Within Object (Missing Block in Record)
12 0C Record on Tape Larger Than Requested
13 0D Compare Error
7DEOH$±,QWHUQDO6WDWXV&RGHV