3D Innovations DLT8000 Gas Grill User Manual


 
7DQGEHUJ'DWD 6&6,&RPPDQGV
7DQGEHUJ'/73URGXFW0DQXDO 
02'(6(/(&7&RPPDQGKKFRQWLQXHG
)LHOG1DPH 'HVFULSWLRQ
PS Parameters Savable. For MODE SELECT, this bit must be 0.
Additional Page
Length
This field indicates the number bytes in the page. However, the
value does not include bytes 0 and 1. The length is returned in
MODE SENSE commands and must subsequently be set to the
same value when performing MODE SELECT. If the page length
does not match that expected by the drive, a CHECK CONDITION
status is returned, sense key set to ILLEGAL REQUEST.
The drive returns a CHECK CONDITION status with sense key set
to ILLEGAL REQUEST if it receives an unsupported Page Code or a
Page field with values not supported or changeable. In such cases,
no parameters are changed as a result of the command.
Maximum
Additional
Partitions
Not supported. Must be 0.
Additional
Partitions Defined
Must be 0. This field specifies the number of additional partitions to
be defined for the tape based on the settings of the SDP and IDP
bits. The maximum allowed is the value returned in the Maximum
Additional Partitions field. Only one partition is supported, therefore
the value of the field must be 0.
FDP Fixed Data Partitions. Must be 0.
SDP Select Data Partitions. Must be 0.
IDP Initiator Defined Partitions. Must be 0.
PSUM Partition Size Unit of Measure. Must be 0.
Medium Format
Recognition
This field is valid for MODE SENSE only, and is set to 01h,
indicating that Medium Format Recognition is supported.
7DEOH±0HGLXP3DUWLWLRQ3DJH'HVFULSWRU²)LHOG'HVFULSWLRQV