7DQGEHUJ'DWD 6&6,&RPPDQGV
7DQGEHUJ'/73URGXFW0DQXDO
(UURU'HWHFWLRQ6XPPDU\LQ/RJ6HOHFW3DJHV
The host issues a LOG SENSE command to initialize host-resident software that
allows determination of:
• The log pages used by the drive
• The parameter codes and length of each parameter
The following conditions constitute errors in the parameter block that cause the
drive to return CHECK CONDITION with sense data set to ILLEGAL REQUEST
and additional send code INVALID FIELD IN PARAMETER LIST:
• A page header is received with unsupported page codes
• An incorrect log page length is specified in the page header
• An illegal parameter code is contained in a valid page code
• Parameter codes for a supported page are not sent in ascending order
• The LP bit (Table 5-18) is set to 1 in the parameter control byte
• The DS bit (Table 5-18) is set to 0 in the parameter control byte
• The TSD bit (Table 5-18) is set to 0 in the parameter control byte