3D Innovations DLT8000 Gas Grill User Manual


 
7DQGEHUJ'DWD 6&6,&RPPDQGV
7DQGEHUJ'/73URGXFW0DQXDO 
02'(6(/(&7&RPPDQGKKFRQWLQXHG
SCSIBUSDMATIMER
ASCII Decimal
2 1 The number of seconds until the drive
times out waiting for ACK once DMA
transfer started. When set to 0, the timer
is set to infinite.
SCSIRESELRETRIES
ASCII Decimal
10 1 The number of reselection retries the drive
makes before giving up. Each reselection
retry occurs every 1 second. When set to
0, the drive does infinite reselection
retries.
SCSIRDYEARLY
ASCII Binary
0 1 The drive reports READY status earlier
(if set).
REPORTRCVRDERR
ASCII Binary
0 1 This parameter sets the default value of
PER bit of READ / WRITE Error Recovery
Mode page (01h).
NORDYUAONUNLD
ASCII Binary
0 1 When set, Not Ready to Ready Transition
unit attention will be removed from the unit
attention queue upon a successful unload.
HOSTCOMPSETTING
ASCII Decimal
0 1 This parameter allows the host to change
the compression setting. Note that there is
a tradeoff between best performance and
best compression; if the compression
setting = 1, it provides the best
performance but the worst level of
compression. If the setting = 15, it
provides lowest performance but
maximum compression. Settings for the
HOSTCOMPSETTING parameter are:
0 Use default compression setting
1 Set compression setting for best
performance
2 Set compression setting for best
compromise of performance and
compression
3 Set compression setting for best
compression
REDUNDANCYMODE
ASCII Decimal
0 1 Sets the value of the allowed maximum
marginal channel (0 - 1 allowed).
REPBUSYINPROG
ASCII Binary
0 1 When set, report busy status if the drive is
in the process of becoming ready.
7DEOH±((35209HQGRU8QLTXH3DJH3DUDPHWHUVFRQWLQXHG