3D Innovations DLT8000 Gas Grill User Manual


 
7DQGEHUJ'DWD 6&6,&RPPDQGV
7DQGEHUJ'/73URGXFW0DQXDO 
/2$'81/2$'&RPPDQG%KFRQWLQXHG
)LHOG1DPH 'HVFULSWLRQ
Immed Immediate. If this bit is set to 1, status is returned as soon as the
operation is started. If set to 0, status is returned after the operation has
completed.
Re-Ten Re-tension. Re-tension operations are not needed on the tape drive. This
bit is ignored (i.e., “good” status, if bit is set to 1).
Load Load. When a cartridge is inserted, the tape medium is automatically
loaded and positioned by the drive at Beginning of Medium (BOM).
Logically, the drive is positioned at the beginning of Partition 0.
If the Load bit is set to 1, and the medium is already loaded, no action is
taken. A “good” status is returned. If the medium was unloaded but the
cartridge was not removed, a Load command causes the tape to be
loaded to Beginning of Partition (BOP) again and made ready.
If the Load bit is set to 0, and the medium is loaded, the drive writes any
buffered data and filemarks to the tape and then rewinds the tape to BOM
and unloads the medium back into the cartridge. The green Operate
Handle indicator on the tape drive’s faceplate illuminates and the
cartridge can be removed from the tape drive. If the medium is already
unloaded, no action is taken. A “good” status is returned.
EOT End of Tape. This bit is ignored by the tape drive unless both the EOT
and Load bits are set to 1, then the drive returns CHECK CONDITION,
ILLEGAL REQUEST data.
7DEOH±/2$'81/2$'&RPPDQG'HVFULSWRU%ORFN²)LHOG'HVFULSWLRQV