3D Innovations DLT8000 Gas Grill User Manual


 
7DQGEHUJ'DWD 6&6,&RPPDQGV
 7DQGEHUJ'/73URGXFW0DQXDO
 /2*6(16(&RPPDQG'K
The LOG SENSE command allows the host to retrieve statistical information
maintained by the tape drive about its own hardware parameters or about the
installed tape medium. It is a complementary command to LOG SELECT.
Bit
Byte
76543210
0 Operation Code (4Dh)
1 Logical Unit Number (0) Reserved PPC SP(0)
2 PC Page Code
3 Reserved
4 Reserved
5 - 6
(MSB)
Parameter Pointer
(LSB)
7 - 8
(MSB)
Allocation Length
(LSB)
9 Unused Reserved Flag Link
)LJXUH±/2*6(16(&RPPDQG'HVFULSWRU%ORFN²'DWD)RUPDW