7DQGEHUJ'DWD 6&6,&RPPDQGV
 7DQGEHUJ'/73URGXFW0DQXDO
5(6(59(81,7&RPPDQGKFRQWLQXHG
)LHOG 'HVFULSWLRQ
3rd Pty When set to 1, it indicates that the Third Party Device ID field is valid.
LongID
When 0, indicates that the third party device associated with the reservation
release has a number smaller than 255 and the ID value can be sent within
the CDB. If set = 1, indicates that the third party device ID is greater than
255, the ID value within the CDB is ignored, and the parameter list length is
at least eight.
Third Party
Device ID
Required and used only when the 3rdPty bit is set, in which case this field
specifies the SCSI ID of the initiator to be granted the reservation of the
logical unit. The drive preserves the reservation until one of the following
occurs:
It is superseded by another valid RESERVE command from the
initiator;
It is released by the same initiator;
It is released by a TARGET RESET message from any initiator;
It is released by a TARGET RESET message from any initiator; or
It is released by a hard reset condition.
The drive ignores any attempt to release the reservation made by any other
initiator. For example, if ID7 sends ID2 a Third Party reservation on behalf
of ID6 (the target at ID2 gets reserved for the initiator ID6), then only ID7
can release the target at ID2 (using a Third Party release). ID6 cannot
release the reservation even though the reservation was made on its
behalf.
FRQWLQXHG
7DEOH±5(6(59(81,7&RPPDQG²)LHOG'HVFULSWLRQV