3D Innovations DLT8000 Gas Grill User Manual


 
7DQGEHUJ'DWD 6&6,&RPPDQGV
 7DQGEHUJ'/73URGXFW0DQXDO
&RPPDQG 2SHUDWLRQ&RGH 6XEVHFWLRQ
REPORT LUNS A0h 5.22
REQUEST SENSE 03h 5.23
RESERVE UNIT (6) 16h 5.24
RESERVE UNIT (10) 56h 5.25
REWIND 01h 5.26
SEND DIAGNOSTIC 1Dh 5.27
SPACE 11h 5.28
TEST UNIT READY 00h 5.29
VERIFY 13h 5.30
WRITE 0Ah 5.31
WRITE BUFFER 3Bh 5.32
WRITE FILEMARKS 10h 5.33
7DEOH±6XSSRUWHG6&6,&RPPDQGVFRQWLQXHG
127(6
1. Relative Addressing is not supported by the tape drive. Therefore, in
all I/O commands, the RelAdr bit must be 0.
2. RESERVE UNIT and RELEASE UNIT by Logical Unit Number are
supported, as are third-party reservations. Extent reservations are
not supported.
3. The RECEIVE DIAGNOSTIC RESULTS and SEND DIAGNOSTIC
DATA commands implement vendor-unique pages to test the drive
during the manufacturing process. It is recommended that initiators
specify only the non-page format variants of these commands
(PF=0), except for page 0x40.
4. The DLT tape drive does not act as an initiator on the SCSI bus.
Therefore, the drive will not 1) generate unsolicited interrupts to the
host, 2) initiate its own SCSI commands, or 3) assert bus reset.
5. Linked commands are supported.