3D Innovations DLT8000 Gas Grill User Manual


 
7DQGEHUJ'DWD 6&6,&RPPDQGV
 7DQGEHUJ'/73URGXFW0DQXDO
02'(6(16(&RPPDQG$K$KFRQWLQXHG
)LHOG1DPH 'HVFULSWLRQ
PS Parameters Savable. Not supported; must be 0.
Page Length The value in this field indicates the number of bytes in the
Control Mode Page being transferred. The value for this byte
is 0Eh.
DCE Data Compression Enable. The value returned for this bit
depends on the current WRITE density of the tape drive:
Value Write Compression is…..
0 Disabled
1 Enabled
DCC Data Compression Capable. The value returned for this bit
indicates whether this tape drive supports data compression
Value Data Compression is…..
0 Disabled
1 Enabled
DDE Data Decompression Enable. The value returned for this bit
indicates whether data decompression is enabled or not.
Value Data Decompression is…..
0 Disabled
1 Enabled
Note that when the tape drive reads compressed data from
tape, it automatically decompresses the data before sending
it to the initiator. The value for this bit, therefore, is always 1.
RED Report Exception on Decompression. The tape drive does
not report exceptions on decompression (boundaries
between compressed and decompressed data). The value
returned for RED is 00h.
Compression Algorithm The value for this field is 10h. This indicates the Lempel-Ziv
high efficiency data compression algorithm.
Decompression Algorithm The value for this field is 10h. This indicates the Lempel-Ziv
high efficiency data decompression algorithm. If EEPROM
parameter EnaRepDCcomp is set, a value of 0 is reported if
the last block read is not decompressed.