7DQGEHUJ'DWD 6&6,&RPPDQGV
 7DQGEHUJ'/73URGXFW0DQXDO
/2*6(16(&RPPDQG'KFRQWLQXHG
/2*3$5$0(7(56
Bit
Byte
76543210
0 -1
(MSB)
Parameter Code
(LSB)
2 DU DS TSD ETC TMC RsvdLP
3 Parameter Length
4 - 11
(MSB)
Parameter Value
(LSB)
)LJXUH±/RJ3DUDPHWHUV)RUPDWIRU5($':5,7((UURU/2*6(16(3DJH
Parameter
Code
Parameter Codes supported for the READ/WRITE error counter pages are as follows:
00h Errors corrected with substantial delays
01h Errors corrected with possible delays
02h Total rewrites or rereads
03h Total errors corrected
04h Total times correction algorithm processed
05h Total bytes processed
06h Total uncorrected errors
8001h Vendor Unique
9001h Vendor Unique
Parameter codes 00h, 01h, and 04h always return a value of 0. Parameter
value for 05h is 8 bytes; the parameter length is set to 8.
7DEOH±/RJ3DUDPHWHUVIRU5($':5,7((UURU/2*6(16(3DJH