Heatiator C40 Fire Pit User Manual


 
Page 50
Heatilator • Constitution EPA Fireplace • 480-1091H
4/12
NAIL
FLASHING
PLATE
CHIMNEY
THIMBLE
EXTENSION
SCREW
FLASHING
THIMBLE
ADJUSTABLE
EXTENSION
HOLES
FLASHING
CHIMNEY
FLASHING
PLATE
NAIL
THIMBLE
SCREW
THIMBLE
EXTENSION
N.
SL-300 Series Ceiling/Roof Thimble
1. Locate the point where the chimney will exit the roof by
plumbing down to the center of the chimney. Lay out, cut
and frame a 14-1/2 in. (368 mm) square opening (measured
on the horizontal) through the ceiling and roof structure.

2. The thimble must extend completely through the roof
structure shielding combustible materials. Five location
holes have been provided to allow for a variety of ceiling/
roof thicknesses. A Thimble Extension is required when the
ceiling/roof thickness exceeds 12-1/2 in. (318 mm). The
extension should overlap the thimble one inch.
3. To attach the extension to the thimble, drill 1/8 in. (3 mm)
holes through the outer shield of the thimble using the
predrilled holes in the extension as guides. Attach the
extension to the thimble using the screws provided with
the extension.
4. Install the thimble assembly and nail it securely to the fram-
ing members.
5. Center the ashing over the chimney and nail it to the roof
using the  nails provided. Keep gaps between
the ashing plate and the roof to a minimum. Caulk the ash-
ing plate and roof junction as well as the vertical seam on
the ashing. All nail heads must be caulked with a roong
sealant.
6. Finish assembling the chimney storm collar and termina-
tion cap following the installation instructions provided with
them.
CHIMNEY
FLASHING
PLATE
JOISTS
NAIL
THIMBLE
FLASHING
Figure 8.15 Installing Part 12966A, Conguration 2

Figure 8.14 Installing Part: 12966A, Conguration 1
Figure 8.16 Installing Part 12966A Conguration 3