Heatilator • Constitution EPA Fireplace • 480-1091H
Page 35
6
Framing & Clearances
Several options are available to you when choosing a loca-
tion for your replace. This replace may be used as a room
divider, installed along a wall, across a corner or used in an
exterior chase. See Figure 6.1
Locating the replace in a basement, near frequently opened
doors, central heat outlets or returns, or other locations of
considerable air movement can affect the performance and
cause intermittent smoke spillage from the front of the re-
place when no outside air is used. Outside air must be used
for combustion. The Constitution comes equipped with an
outside air inlet to feed combustion air from outside the
home, along with an outside air termination cap. Consider-
ation should be given to these factors before deciding on a
location. See Sections 4 and 5.
D
C
A
E
F
A
H
G
B
A
B
B
A
I
In an exterior chase
or projecting into a
garage
Across a corner
Along a wall
As a
room
divider
24 in.
(610mm)
24 in.
(610mm)
24 in.
(610mm)
48 in.
(1219mm)
Model:
Constitution
(Dimensions for
nished walls)
A B C D E F G H I
41-7/8 16 89-1/2 63-5/16 22-7/16 44-3/4 14-1/16 55-15/16 50-7/8
1063 406 2273 1608 570 1137 357 1421 1292
Figure 6.1 Fireplace Locations
A. Selecting Fireplace Locations