The decorative fascia must be removable for future service-
ability of the Automatic Combustion Control.



         


 



D. Electrical Access and Wiring Diagram




1. Remove junction box cover plate on the bottom right side
of the replace.
2. Thread the 14-3 with ground wire through the opening
with the strain relief on the cover plate.
3. Match colors to wire harness, (red to red, white to white,
etc) and secure with wire nuts.
  


Figure 6.4 Fan Wiring Diagram
14-2 w/ground
Standard wall mount with
Junction Box
14-3 w/ground
WIRE NUT
WHITE
GREEN
BLACK
BLACK
RED
WHITE
Match colors to wire
harness (red to red,
white to white, etc) and
secure with a wire nut
Incoming Power
(110V)
Power to the Fireplace
Snap Disc
bypass switch
Maintain clearances.
Use only non-combustible material below standoffs,
material such as cement board is acceptable.
Framing or nishing material used on the front of, or
in front of, the appliance closer than the minimums
listed, must be constructed entirely of noncombustible
materials (i.e., steel studs, concrete board, etc.).

