Heatiator C40 Fire Pit User Manual


 
Page 46
Heatilator • Constitution EPA Fireplace • 480-1091H
4/12
R
OO
M AB
O
VE
(
non-insulated ceiling
)
ATTIC ABOVE (insulated ceiling)
B
A
Ceilng firestop
attached to bottom
of framing
Ceiling firestop
attached to top of
framing
When attic insulation
shield not used
Note: Use same dimensional lumber for framing
ceiling firestop and joists.
2 in. (51mm)
clearance
2 in. (51mm)
clearance
Figure 8.7 Installing the Ceiling Firestop
Catalog #
A B
   
FS338 14-1/2 368 14-1/2 368
FS339 14-1/2 368 18-3/8 467
FS340 14-1/2 368 23 584
Wire Ties
Wire Ties
4" Flex
Figure 8.6 Installing Flex Pipe


 Chase construction requires ceiling restops at each oor
or every 10 ft (3.05 m) of clear space.
The ceiling restop slows spread of re and reduces cold
air inltration.
Install a ceiling restop whenever chimney penetrates
ceiling/oor.
Mark and cut an opening in ceiling as shown in Figure 8.7.
Frame the opening with the same size lumber used in
the ceiling joists.
Nail the ceiling restop to the bottom of the ceiling joists
when there is a room above.
Use an attic insulation shield if the ceiling is insulated.
The ceiling restop may then be attached above or below
the joists.


   

F. Install Ceiling Firestops