Hearth and Home Technologies Crescent II Outdoor Fireplace User Manual


 
Heat & Glo • Crescent II • 2083-902 Rev. G • 9/0542
Maintaining and Servicing Appliance
15
Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualified service
technician should perform an appliance checkup at the beginning of each heating season.
WARNING
Annual inspection by qualified technician recommended.
Check:
Condition of doors, surrounds and fronts.
Condition of glass, glass assembly and glass seal.
Obstructions of combustion and ventilation air.
Condition of logs.
Condition of firebox.
Burner ignition and operation.
Burner air shutter adjustment
Gas connections and fittings.
Obstructions of termination cap.
Clean:
Glass
Air passageways, grilles,
control compartment
Burner, burner ports
Risk of:
Fire
Delayed ignition or explosion
Exposure to combustion fumes
Odors
Handle glass assembly with care.
NOTE: Clean glass after initial 3-4 hours
operation. Longer operation without
cleaning glass may cause a permanent
white film on glass.
CAUTION
When cleaning glass door:
Avoid striking, scratching or slamming glass.
Do NOT use abrasive cleaners.
Use a hard water deposit glass cleaner on white film.
Do NOT clean glass when hot.
Turn off appliance after 3-4 hours of operation and
ALLOW TO COOL.
Remove and clean glass assembly.
Replace glass assembly and operate appliance for
additional 12 hours.
Refer to maintenance instructions.
Risk of injury or property damage.
Before servicing:
Turn off gas.
Turn off electricity to appliance.
Disable remote control, if one is present.
Ensure appliance is completely cooled.
After servicing:
Replace any screen or barrier that was removed.
Reseal and reinstall any venting removed for servicing.
WARNING
Inspect external vent cap regularly.
Ensure no debris blocks cap.
WARNING
Combustible materials blocking cap may ignite.
Restricted air flow affects burner operation.