A. Recommendation for Wire
This appliance requires 110-120 VAC be wired to the junction
box for proper operation of the appliance (Intellifire ignition).
Electrical Information
10
NOTE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA 70-
latest edition or the Canadian Electric Code, CSA C221.1.
B. Connecting to the Appliance
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
Incorrect wiring will damage millivolt valves.
Incorrect wiring will override IPI safety
lockout and may cause explosion.
This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
If using thermostat use one compatible with a millivolt
gas valve system.
Follow parameters for locating thermostat (see individual
thermostat instructions) to ensure proper operation of
appliance.
Use low resistance thermostat wire for wiring from igni-
tion system to the wall switch and thermostat.
Keep wire lengths short as possible by removing any
excess wire length.
Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
C. Intellifire Ignition System Wiring and
3 Function Circuit Board
This appliance requires a 110 VAC supply to the appliance
junction box for operation. A wiring diagram is shown in
Figure 10.1.
This appliance is equipped with an Intellifire control valve
which operates on a 3 volt system.
This appliance is equipped with a 3 function circuit board
which operates on 110 VAC and 12 VDC.
This appliance is supplied with a 3 volt AC transformer and
a 12 volt DC transformer, which requires the installation of
the supplied junction box. It is highly recommended that
the junction box be installed at this time to avoid
reconstruction.
Optional Remote Control Requirements
To attach remote receiver in series with 3 function wall switch
see wiring diagram (Figure 10.2).
CAUTION
Label all wires prior to disconnection when servicing con-
trols. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
Shock hazard.
Replace damaged wire with type 105
O
C
rated wire.
Wire must have high temperature insulation.