Hearth and Home Technologies Crescent II Outdoor Fireplace User Manual


 
Heat & Glo • Crescent II • 2083-902 Rev. G • 9/0512
Figure 5.3
Figure 5.4
D. Vent Diagrams
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between firestops.
ALWAYS maintain specified clearances around venting and firestop systems.
Install firestops as specified.
Failure to keep insulation or other material away from vent pipe may cause fire.
WARNING
1. Top Vent - Horizontal Termination
One Elbow
Two Elbows
V
1
H
1
H
2
H
1
V
1
INSTALLED
HORIZONTALLY
V
1
Minimum H
1
Maximum
Elbow only 2 ft 610 mm
6 in 152 mm 2 ft 610 mm
1 1/2 ft 457 mm 3 ft 914 mm
2 1/2 ft 762 mm 5 ft 1.5 m
3 1/2 ft 1067 mm 7 ft 2.1 m
4 1/2 ft 1.4 m 15 ft 4.6 m
V
1
+ H
1
= 38 ft (11.6m) Maximum
H
1
= 15 ft (4.6 m) Maximum
V
1
Minimum H
1
+ H
2
Maximum
2 - 90
0
elbows back
to back
Cannot do
6 in 152 mm 2 610 mm
1 1/2 ft 457 mm 3 ft 914 mm
2 1/2 ft 762 mm 5 ft 1.5 m
3 1/2 ft 1067 mm 7 ft 2.1 m
4 1/2 ft 1.4 m 15 ft 4.6 m
V
1
+ H
1
+ H
2
= 38 ft (11.6 m) Maximum
H
1
+ H
2
= 15 ft (4.6 m) Maximum