Hearth and Home Technologies Crescent II Outdoor Fireplace User Manual


 
Heat & Glo • Crescent II • 2083-902 Rev. G • 9/0520
Assembling DVP-12A Slip Sections
The outer flue of the slip section should slide over the outer
flue of the pipe section and into (inner flue) the last pipe
section (see Figure 8.6) .
Slide together to the desired length, making sure that a
1-1/2 inch outer flue overlap is maintained between the
pipe section and slip section.
The pipe and slip section need to be secured by driving
two screws through the overlapping portions of the outer
flues using the pilot holes (see Figure 8.7).
This will secure the slip section to the desired length and
prevent it from separating. The slip section can then be
attached to the next pipe section.
If the slip section is too long, the inner and outer flues of
the slip section can be cut to the desired length.
Assembling Minimum Installations (MI) Sections
MI sections are non-unitized so that they can be cut to a
certain length. Cut these sections to length from the non-
expanded end (see Figure 8.5).
They can then be attached by first connecting the expanded
end of the MI inner flue with the inner pipe from the adjacent
pipe section and securing with three screws. The expanded
portion of the MI inner flue must overlap completely with
the unexpanded end of the adjacent pipe section.
The outer flue can then be inserted into the adjacent outer
flue expanded end and attached to the next pipe section
with three screws. The other end of the MI pipe section
can then be attached by fitting another pipe section to it
and snapping it together, as normal.
Figure 8.6 Slip Section Pilot Holes
Figure 8.7 Screws into Slip Section
Figure 8.5