Hearth and Home Technologies Crescent II Outdoor Fireplace User Manual


 
Heat & Glo • Crescent II • 2083-902 Rev. G • 9/0522
C. Installing Heat Shield and Horizontal Termination Cap
NOTE: Where required, an exterior wall flashing is
available.
When penetrating a brick wall, a brick extension kit
is available for framing the brick.
Heat Shield Requirements for Horizontal Termination
For all horizontally vented appliances, a heat shield MUST
be placed one inch above the top of the vent between the
wall shield and the base of the termination cap.
There are two sections of the heat shield. One section
attaches to the wall shield with two screws. The remaining
section is attached to the cap in the same manner.
If the wall thickness does not allow the required 1-1/2 inch
heat shield overlap, an extended heat shield must be used.
The extended heat shield will need to be cut to the
thickness of the wall and be attached to the wall shield.
The small leg on the extended heat shield should rest on
the top of the vent (pipe section) to properly space it from
the pipe section (see Figure 8.12).
Installing the Horizontal Termination Cap
Vent termination must not be recessed in the wall. Siding
may be brought to the edge of the cap base.
Caulk the outside edges of the cap (see Figure 8.12).
When installing a horizontal termination cap, follow the cap
location guidelines as prescribed by current ANSI Z223.1
and CAN/CGA-B149 installation codes.
Figure 8.12 Venting through the Wall
Fire Risk
Exhaust Fumes Risk
Impaired Performance of Appliance
Overlap pipe slip sections at least 2 inches.
Use pilot holes for screws.
Screws must not exceed 1 inch long.
Pipe may separate if not properly joined.
WARNING
Burn Risk
Local codes may require installation of
a cap shield to prevent anything or
anyone from touching the hot cap.
WARNING
WARNING
Fire Hazard
Impaired performance of appliance
Telescoping flue section of termination cap
MUST be used when connecting pipe
section to termination cap.
Maintain a 1-1/2 inch minimum overlap on
telescoping flue section of termination cap.
INTERIOR
EXTERIOR
SHEATHING
HEAT SHIELD OR
EXTENDED
HEAT SHIELD
REAR VENT
HEAT SHIELD
1-1/2 IN. MIN.
OVERLAP
WALL SHIELD
INNER VENT
OUTER VENT