Hearth and Home Technologies Crescent II Outdoor Fireplace User Manual


 
Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05
29
Figure 10.2 Intellifire Pilot Ignition (IPI) Wiring Diagram with optional remote wired in series
REMOTE RECEIVER
IGNITION MODULE 3 VAC
INTERMITTENT PILOT IGNITOR
VALVE
ORG
WHT
ORG
GRN
SWITCH
CIRCUIT BOARD
12VDC
LIGHT SOCKET
SOLENOID (NG ONLY)
J-BOX
BLACK
GREEN
RED
YELLOW
WHITE
BLACK
BROWN
BROWN
MADE IN
CANADA
50-025302-D
++
P2
HIHI
12V
COM
C1
C2
R1
P1
REM
REM
D1
J1J1
D2
C2
K3
K2
R4
K1
R1
D3
C1
PRESS. SW
T16
T15
LINE NEU
SOLENOID
T13
T12
T11
1C
3
2
EMBER LIGHTS
HI/LOW
T14
T13
T12
T11
T10
T9
1
C
OFF/ON
3
2
EMBER
T6
T5
IPI
T2
T1
PLUG-IN
J-BOX
BLACK WIRE
CAN BE
PLUGGED INTO
ANY OF #1 - #5
LOCATIONS
ON THE
HOT SIDE
WHITE WIRE
CAN BE
PLUGGED INTO
A
NY OF #1 - #5
LOCATIONS
ON THE
NEUTRAL SIDE
PLUG-IN
J-BOX
TRANSFORMER
3 VAC
GROUND TO
FIREPLACE CHASSIS
S
I