Vermont Casting DVT38S2IN Outdoor Fireplace User Manual


 
8
Chateau™ Direct Vent Gas Fireplace
20011957
Control System
The gas control system is located on the right hand side
of the firebox behind an access panel and the decora-
tive brick panel. The fireplace is operated using only
the hand held remote control unit. The system wiring
diagram is shown in Figure 11. NOTE: If you choose
to install the battery back-up, Model DVTBBK, refer
to Item #16 in the next section.
Control System Installation
1. Locate the fireplace in the desired location.
2. Remove the glass. Refer to Glass Frame Assembly
Removal section.
3. If installed, remove the lava rock, volcanic rock,
andirons, embers and logs, making note of each
log’s location.
4. If installed, remove the refractory brick panel on
gas supply side.
5.
Using a back-up wrench, disconnect the gas supply
fitting. (Fig. 7)
11. Connect a 120V AC electrical supply to the junc-
tion box duplex outlet. Use a Romex-type strain
relief connector when running wires out through the
box knockout. Replace the duplex outlet and cover
plate.
12. Plug the AC adaptor plug into the duplex outlet.
13. This control system must now be programmed to
the hand held remote control transmitter. To pro
-
gram the remote control, make sure the 120V AC is
connected and powered to the fireplace.
14. Remove the battery door on the back of the hand
held remote control and install two (2) supplied
“AAA” batteries. Be sure to note correct polarity.
Replace battery door.
15. Locate the learn button on the main module. (Fig.
9) Press and release the learn button using a pencil
point. There will be a beep sound from the module.
Then press any key on the remote control transmit-
ter. Once the module’s internal receiver accepts the
transmitter code, there will be a series of confirming
beeps.
16. If you chose to install the optional back-up battery
pack (No. DVTBBK), you must install a wall box
from 3’ (914 mm) to within 15 feet (4.6 m) of the
fireplace. Assemble the connectors on one end of
the supplied extension wire harness to the mating
connectors on wire harness within the control box.
Make sure to connect black coded wire to black
and red coded wire to red.
17. The other end of the extension wire harness should
be connected to the wiring of the back-up battery
holder located within a wall box.
18. Insert the supplied four (4) “AA” batteries into the
battery older. Be sure to note correct polarity for
each battery.



Cover
Plate
Gas Sup-
ply Fitting
FP1801
Fig. 7 Disconnect gas supply fitting and remove 13 screws
securing the cover plate.
6. Remove pilot assembly from burner assembly by
removing two (2) screws.
7. Carefully slide the burner assembly out of the way,
taking care not to bend or break the pilot tubes or
wiring.
8. Remove 13 screws around the perimeter holding
large access panel on the side of the firebox.
9. Carefully pull back the panel just enough to gain
access to control box.
10. Connect the gas supply to the valve. (Fig. 8) Be
sure to use a back-up wrench when tightening sup-
ply fitting.



Gas Supply
Fitting
Learn Button
FP1802
Fig. 8 Connect gas supply to valve.
Pressure
Test
Ports