Vermont Casting RADVTCG Outdoor Fireplace User Manual


 
66
Radiance Direct Vent Gas Heater
20012697
Parallel Installation:
Minimum Clearance and Flue Centerline
Fig. 3 Parallel installation, minimum back and side clear-
ances, and flue centerlines.
ST130



42" (1070mm)
Min. Alcove Width
48"
(1220mm)
Max. Alcove
Depth
6"
(150mm)
6"
(150mm)
4" (102mm)
ST129



18"
(457mm)
18"
(457mm)
6"
(150mm)
6"
(150mm)
Corner Installation:
Minimum Clearance and Flue Centerline
Fig. 4 Corner installation, minimum corner clearances and
flue centerline.
Wall Centerline from Floor
ST131b
Stardance
wall thimble
9/28/00 djt
A
A
Effective Minimum
Centerline 57” (1448 mm)
(CFM Corporation Pipe)
55” (1399 mm) (Simpson DuraVent Pipe)
ST131b
Fig. 5 Minimum wall centerline.
Direct Vent Only
Hearth Requirements
The Radiance Heater must be installed on rigid flooring.
When the heater is installed directly on any combustible
surface other than wood flooring, a metal or wood panel
extending the full width and depth of the unit must be
used as the hearth. There are no other hearth require-
ments.
* needed for installing DuraVent Minimum Vent Kit #2792 or
CFM Corporation Minimum Vent Kit #7TFSMSK.
A
C
D
ST101b
Stardance
Direct Vent
Min. Clrnc
9/28/00 djt
B
A: Rear Wall 4” (102 mm)
B: Min. Clearance 44” (1118 mm)*
C: Min. Alcove Height 72” (1830 mm)*
D: Max. Alcove Depth 48” (1220 mm)
Sidewall Clearance 6” (150 mm)
ST101b
Fig. 6 Dimensions and clearances to ceiling or alcove.
Direct Vent Only
Wall and Ceiling Clearances