Vermont Casting 36CDVTRN Fire Pit User Manual


 
33
CDV Series Direct Vent Gas Fireplace
20010175
The conversion of this appliance from one
gas to another must be carried out by an
authorized service provider.
1. Disconnect power to the unit and shut off the gas sup
-
ply.
2. Remove window frame assembly.
3. Carefully remove the logs & lava rock material.
4. Remove the screws that are holding the burner hous-
ing in place.
5. Remove the burner housing assembly. Depending on
the model of the appliance you may have to loosen
the pilot bracket retaining screw/nut to allow the pilot
and bracket assembly to tilt and give enough clear-
ance to remove the burner housing assembly.
6. Remove the main burner orifice and replace it with the
orifice supplied in the conversion kit.
7. SIT top Convertible Pilot
Gently lift off the pilot hood from the pilot. (Do not re-
move the spring clip holding the hood in place). Using
a 5/32” Allen key, unscrew the exposed orifice. Insert
the new orifice supplied in the kit, do not over tighten
the orifice. Replace the pilot hood ensuring the index
tab aligns with the notch on the hood.
8. SIT 820 NOVA Gas Control Valve (Fig. 62)
a. Using a Torx T20 or slotted screwdriver, remove
and save the three pressure regulator mounting
screws (A), pressure regulator tower (B) and
diaphram (C).
b. Ensure the rubber gasket (D) is properly positioned
and install the new HI/LO pressure regulator to the
valve using the new screws (E) supplied with the
kit. Tighten screws securely. (Reference torque - 25
in.LB)
c. Install the enclosed identification label (F) to the
valve body where it can be easily seen.
9. Reassemble the fireplace in the reverse order, except
for the window frame assembly. Leave this off until
after the unit has been checked for leaks and the gas
supply has been bled.
10. After bleeding the gas line and checking for leaks with
a soap solution, replace the window frame assembly.
Fire up the unit, check for flame impingement on the
logs, adjusting them if necessary. Check the manifold
and supply pressures against the appliance specifica-
tions.
Fuel Conversion Instructions
The procedure for converting from one gas to
another is the same regardless of the initial
gas used. The only variation is in the orifice
sizes and component part numbers. Your
authorized service provider will ensure the
correct parts are used.
Fig. 62 Nova SIT820 Gas Valve.
D
E
F
FC108
SIT
regulator
conversion
10/03
O
F
F
P
I
L
O
T
O
FC107
SIT820
valve conversion
10/03
A
B
C
O
F
F
P
I
L
O
T
O
FC107/108