Napoleon Fireplaces GD82NT-PA Fire Pit User Manual


 
5
W415-0665 / B / 02.11.08
This gas fireplace should be installed and serviced by a qualified
installer to conform with local codes. Installation practices vary
from region to region and it is important to know the specifics that
apply to your area,
for example: in Massachusetts State:
• The fireplace damper must be removed or welded in the open
position prior to installation of a fireplace insert or gas log.
• The appliance off valve must be a “T” handle gas cock.
• The flexible connector must not be longer than 36 “.
• The appliance is not approved for installation in a bedroom or
bathroom unless the unit is a direct vent sealed combustion
product.
• A carbon monoxide detector is required in all rooms containing
gas fired appliances.
• WARNING: This product must be installed by a licensed
plumber or gas fitter when installed within the commonwealth of
Massachusetts.
In absence of local codes, install to the current CAN/CGA -B149
Installation Code in Canada or to the National Fuel Gas Code,
A
NSI Z223.1, and NFPA 54 in the United States. Suitable for
mobile home installation if installed in accordance with the current
standard CAN/CSA Z240MH Series, for gas equipped mobile
homes, in Canada or ANSI Z223.1 and NFPA 54 in the United
States.
The fireplace and its individual shutoff valve must be discon-
nected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psig (3.5
kPa). The fireplace must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.5 kPa).
When the fireplace is installed directly on carpeting, vinyl tile or
other combustible material other than wood flooring, the fireplace
shall be installed on a metal or wood panel extending the full
width and depth.
The optional heat circulating blower is supplied with a cord. If
installed, the junction box must be electrically connected and
grounded in accordance with local codes. In the absence of local
codes, use the current CSA C22.1 canadian electrical code in
Canada or the ANSI/NFPA 70 national electrical code in the
United States.
Provide adequate ventilation and combustion air.
Provide adequate accessibility clearance for servicing and
operating the fireplace. Never obstruct the front opening of
the fireplace.
Objects placed in front of the fireplace must be kept a
minimum of 48” from the front face of the unit.
GENERAL INSTRUCTIONS
GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN
TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY!
Maximum input is 26,000 BTU/hr for both natural gas and
propane. When the fireplace is installed at elevations above
4,500ft, and in the absence of specific recommendations from
the local authority having jurisdiction, the certified high altitude
input rating shall be reduced at the rate of 4% for each additional
1,000ft. Maximum output for natural gas is 16150 BTU/hr at an
efficiency of 62%; and 16150 BTU/hr for propane at an efficiency
of 62%. Minimum inlet gas supply pressure is 4.5 “ water column
for natural gas and 11 “ water column for propane. Maximum inlet
gas pressure is 7 “ water column for natural gas and 13 “ water
column for propane. Manifold pressure under flow conditions is
3.5 “ water column for natural gas and 10 “ water column for
propane.
This fireplace is certified to be installed in an aftermarket
permanently located, manufactured (mobile) home, where not
prohibited by local codes.
No external electricity (110 volts or 24 volts) is required for the
gas system operation.
This
f
ireplace is only
f
or use with the type o
f
gas indicated on the
rating plate. This fireplace is not convertible for use with other
gases, unless a certified kit is used.
Expansion / contraction noises during heating up and cooling
down cycles are normal and are to be expected. Change in flame
appearance from “HI” to “LO” is more evident in natural gas than
in propane.
This fireplace is approved for bathroom, bedroom and bed-sitting
room installations and is suitable for mobile home installation.
The inner stainless steel looking firebox back will discolour with
heat, turning a light brown, straw like colour that is to be consid-
ered normal.
Do not use abrasive cleaners to clean glass. Buff lightly with a
clean dry cloth. The glass is 3/16” ceramic glass available from
your Napoleon® / Wolf Steel Ltd. dealer. Do not substitute
materials. Clean the glass after the first 10 hours of operation with
a recommended gas fireplace glass cleaner. Thereafter clean as
required. Do not clean glass when hot! If the glass is not kept
clean permanent discolouration and / or blemishes may result.
CARE OF GLASS
We Suggest that our gas
hearth products be installed
and serviced by profession-
als who are certified in the
U.S. by the National Fire-
place Institute (NFI) as NFI
Gas Specialists.
Do not use abrasive cleaners to clean glass. Buff lightly with a
clean dry cloth. The glass is 3/16” ceramic glass available from
your Napoleon® / Wolf Steel Ltd. dealer. Do not substitute
materials. Clean the glass after the first 10 hours of operation with
a recommended gas fireplace glass cleaner. Thereafter clean as
required. Do not clean glass when hot! If the glass is not kept
clean permanent discolouration and / or blemishes may result.
CARE OF GLASS
We Suggest that our gas
hearth products be installed
and serviced by profession-
als who are certified in the
U.S. by the National Fire-
place Institute (NFI) as NFI
Gas Specialists.