DCS "BGB" Series Gas Grill User Manual


 
16
GENERAL:
A
lthough all gas connections on the grill are leak tested at the factory prior to shipment, a complete gas
tightness check must be performed at the installation site due to possible mishandling in shipment, or excessive
pressure unknowingly being applied to the unit. Periodically check the whole system for leaks, or immediately
check if the smell of gas is detected.
Before Testing:
Do not smoke while leak testing. Extinguish all open flames. Never leak test with an open flame. Make a
soap solution of one part liquid detergent and one part water. You will need a spray bottle, brush, or rag to
apply the solution to the fittings. For LP units, check with a full cylinder. The valve panel must be removed to
check the valves and fittings. Remove the knobs and the safety valve knob, then remove the 2 screws which
fasten the valve panel to the unit (you will need a Philips screw driver for this). Pull the valve panel outward and
unplug the wires from the ignition module and the back of the ignition button. In the back of the unit remove
the scr
ews which hold the service panel in place. Remove the service panel.
To Test:
Make sure all control valves are in the “OFF” position. Turn the gas supply “ON”. Check all connections from the
supply line, or LP cylinder up to and including the manifold pipe assembly. Apply the soap solution around the
connection, valve, tubing and end of the manifold. Soap bubbles will appear where a leak is present. If a leak is
present, immediately turn off gas supply, tighten any leaking connections, turn gas on, and recheck. Check all
the gas connections at the base of the control valves where they screw into the manifold pipe.
To check rotisserie burner and safety valve the burner must be lit, then leak test the connections located behind
the service panel. If you cannot stop a gas leak turn off the gas supply and call your local gas utility, or the
dealer you purchased the appliance from. Only those parts recommended by the manufacturer should be used
on the grill. Substitution can void the warranty.
WARNING!
Do not use the g
rill until all connections have been checked and do not leak.
Check all gas supply fittings for leaks before each use. Keep a spray bottle of soapy water near the gas supply
shut-off valve. Spray all the fittings. Bubbles indicate leaks (Fig. 16 & 17).
Bottom of unit
CHECK HOSE FOR
SIGNS OF ABRASIONS,
CRACKS, OR LEAKS
LEAK TEST POINTS
LP TANK
Bottom of unit
LEAK TEST POINTS
INSTALLATION
LEAK TESTING
FIG. 16 LP G
as
FIG. 17 Nat. Gas