Special offers from our partners!
Find Replacement BBQ Parts for 20,308 Models. Repair your BBQ today.
14
INSTALLATION
GAS HOOK-UP
LP TANK RESTRAINT FOR BUILT-IN INSTALLATION
If the grill is to be installed in a Built-in application, then the grill must be installed in accordance with the
B
uilt–in installation guidelines.
If you intend to operate your Built-in grill on LP gas utilizing a 20 lb Type 1 cylinder, then the Built-in LP tank
r
estraint must be installed prior to initial use of the grill. If you do not have one please contact DCS Customer
Care at (888) 936-7872 for information on obtaining one.
The following steps will illustrate how to properly locate and install the LP tank restraint within the Built-in
enclosure.
NOTE:
The grill comes with the LP Regulator/Hose assembly installed at the factory. The assembly, along with the entire grill
system, is leak tested.
Do not remove the Regulator/Hose assembly from the grill during installation.
FIG. 10
18” max.
The maximum distance from the center
of the manifold cut out to the center of
the tank restraint is
18 inches.
C
enter of manifold
cut out projected to
floor of the island.
C
ent
er of
T
ank Restraint must be
plac
ed within this ar
ea to avoid
causing stress on the LP regulator
hose c
onnec
tion.