Taylor QS22 Electric Grill User Manual


 
18
Models QS10 & QS22Operating Procedures
Step 4
Place the release material clips over the release
material sheet, pressing them into place over the
release material bar at the top of the platen.
Figure 12
Step 5
Check the alignment and tightness of the release
material against the upper platen.
Step 6
Repeat steps 1 through 5 for the remaining upper
platen(s) on the QS22.
Note: It is not necessary to change the release
material if small pin holes develop.
The release material must be changed when:
S Product sticks to the release material.
S Carbon builds up, causing problems in taste
or appearance.
S There is a tear in the release material in the
cooking area.
S The release material substance is worn from
the release material sheet.
S The temperature of the upper platen drops
more than 10_F. (5.6_C.) from the tempera-
ture recorded when the release material was
removed.
Note: Temperature checks should only be con-
ducted with the release material sheets removed.
Note: Rotate and reverse the release material
sheets on a daily basis.
Care of Release Material Sheets
S DO NOT fold or crease.
S DO NOT touch with any sharp object or
abrasive.
S DO NOT hose with hot water or soak in
water.
S DO NOT place under other objects.