Regency IG35-LPG Fire Pit User Manual


 
9
Regency IG35 Gas Inbuilt Fireplace
INSTALLATION
Conversion Kit #486-968 for NG to LPG Model
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Conversion Kit 486-968 Contains:
Qty. Part # Description
1 904-645 Burner Ori ce #51
1 908-528 Red "LPG" label
1 918-590 Label "Converted to LPG"
1 918-541 Instruction Sheet
1) Shut off the gas supply and unplug the power
cord.
2) Remove the front door.
3) Remove logs.
4) Remove the rear log tray by removing the 2
screws. (Log tray must be rotated to clear
the burner.)
Control Box
Cover
Antenna
13) Remove the control box cover by undoing the
3 screws. Maneuver through antenna.
Jumper Location
Jumper
14) Remove the jumper using a plier.
5) Remove the grate.
6) Remove the burner and adjust the aeration
setting to 15 mm fully open.
7) Remove burner ori ce with a 1/2" wrench
and discard. Use a wrench to hold on to the
elbow behind the ori ce.
8) Reinstall new burner ori ce LPG stamped
#51 and tighten.
9) Stick the conversion label "This unit has
been converted to LPG" over top of the serial
number decal.
10) Replace the yellow "NG" label with the red
"LPG" label.
11) Carefully pull out the control box.
NOTE: The control box is held in place with
velcro.
12) Remove the heat shield from the control
box by removing the 2 screws.
15) Reverse steps 13, 12, 11, 6, 5, 4, 3 & 2.
Heat Shield