INSTALLATION
IMPORTANT
MESSAGE
The Regency Gas Fireplace must be installed
in accordance with these instructions. Carefully
read all the instructions in this manual rst.
Note: Failure to follow these instructions
could cause a malfunction of the
heater which could result in death,
serious bodily injury, and/or prop-
erty damage. Failure to follow these
instructions may also void your re
insurance and/or warranty.
FOR YOUR SAFETY
This appliance requires air for proper combus-
tion. Always provide adequate combustion and
ventilation air. Follow instructions and informa-
tion in the current AS5601-2004, NZS 5261
or local codes. Consult the "authority having
jurisdiction" to determine the need for a permit
prior to starting the installation.
BEFORE YOU START
Installation is to be carried out ONLY by an
authorised person.
1) The appliance shall be installed in accord-
ance with the manufacturer's installation
instructions, local gas tting regulations,
municipal building codes, water supply
regulations, electrical wiring regulations,
with AS5601-2004. (AGA gas installation
code) NZS 5261(New Zealand)
2) Installation and repair should be done
ONLY by an authorised person.
3) The appliance should be inspected before
use and at least annually by an authorised
service person. More frequent cleaning may
be required due to excessive lint from carpet-
ing, bedding material, etc. It is imperative
that control compartments, burners and
circulating air passageways of the appliance
be kept clean and free from excessive lint
from carpeting.
4) See general construction and assembly
instructions. This appliance may only be in-
stalled in a ued, non-combustible replace.
The appliance and ue should be enclosed
when installed or passing through a living
area, where children may come in contact
with it.
This appliance can also be installed into the
approved Zero Clearance Kit #486-900 in a
combustible situation.
5) Always connect this space heater to a chim-
ney and ue to the outside of the building
envelope. Never ue to another room. Make
sure that the ue is properly sized and is
of adequate height to provide the proper
draft.
6) Inspect the ueing system annually for
blockage and any signs of deterioration.
7) Any safety glass removed for servicing
must be replaced prior to operating the ap-
pliance.
8) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
replace.
MATERIALS REQUIRED
A 240 Volt AC power cord is hooked up to the
unit. Plug 3 wire cord into a suitable receptacle.
Do not cut the ground terminal off under any
circumstances.
When connected with 240 volts, the appliance
must be electrically grounded in accordance
with local codes.
This unit is polarity sensitive and will not oper-
ate if polarity is incorrect.
INSTALLATION
CHECKLIST
The Regency Gas Insert is installed as listed
below.
1) Unit Location - refer to "Clearances to
Combustibles" section.
2) Make the gas connections. Refer to "Gas
Connections" section.
3) Install the ue or liner to the ue collar. Refer
to "Flueing" section.
4) Slide the unit into the replace.
5) Test gas pressure, refer to "Gas Pipe Pres-
sure Testing" section. Check aeration, refer
to "Aeration Settings" section.
6) Test for ue spillage, refer to "Test for Flue
Spillage" section.
7) Install the optional brick panels. Refer to
"Optional Brick Panels" section.
8) Install the log set. Refer to "Log Set instal-
lation" section.
9) Assemble and install the faceplate and trim
and louvres. Refer to "Faceplate, Trim &
Louvre" section.
10) Optional Premium Flush Front installation.
Refer to "Premium Flush Front Installation"
section.
11) Final check: Before leaving this unit with the
customer, the installer must ensure that the
appliance is ring correctly. This includes:
a) Clocking the appliance to ensure the
correct ring rate.
b) Adjusting the primary air, if required,
to ensure that the ame does not car-
bon.
c) Ensuring that the appliance is ueing
correctly. Refer to "Test for Flue Spillage"
section.
9) Installer must mechanically attach the sup-
plied label to the inside of the rebox of the
replace into which the gas replace insert
is installed.
"WARNING: This replace has been converted
for use with a gas replace insert only and
cannot be used for burning wood or solid fuels
unless all original parts have been replaced,
and the replace re-approved by the authority
having jurisdiction."