Jackson 700 Series Gas Grill User Manual


 
7
4. Leak test the connection. See “leak test”.
5. Refer to lighting instructions. To avoid activating the
Flow Limiting Device when lighting, open the cylinder
valve slowly with the appliance valves off. If the Flow
Limiting Device is accidentally activated, turn off
cylinder valve and appliance valves, wait 10 seconds to
allow the device to reset, open cylinder valve slowly,
then open the appliance valve.
IMPORTANT SAFETY INFORMATION;
THE PRESSURE REGULATOR AND HOSE ASSEMBLY SUPPLIED WITH THIS OUTDOOR COOKING
APPLIANCE MUST BE USED. REPLACEMENT PRESSURE REGULATORS AND HOSE ASSEMBLIES
MUST BE THOSE SPECIFIED BY THE OUTDOOR COOKING GAS MANUFACTURER.
A. Do not store a spare LP-gas cylinder under or near this appliance.
B. Never fill the cylinder beyond 80% full.
IF THE INFORMATION IN “A” AND “B” IS NOT FOLLOWED EXACTLY, A FIRE CAUSING DEATH OR
SERIOUS INJURY MAY OCCUR.
LEAK TEST:
1. DO NOT USE OR PERMIT SOURCES OF IGNITION IN THE AREA WHILE DOING THE LEAK TEST.
THIS INCLUDES SMOKING.
2. Leak testing should be done once per year or whenever the LP gas cylinder or any other gas system part
is replaced, whichever is more frequent.
3. The leak testing solution should be half liquid detergent and half water.
4. Apply the solution to the LP gas delivery system at points shown in the illustration.
5. Bubbles in the soap solution indicate that a leak is present.
6. The leak(s) must be stopped by tightening the loose joints, if possible, or by replacing the faulty parts(s)
with the part(s) recommended by the appliance manufacturer.
THE APPLIANCE IS NOT TO BE USED UNTIL ANY LEAK IS CORRECTED.
A gas appliance repairman or LP gas dealer should be called if attempts to stop the leak(s) are unsuccessful
and, in such case, the LP gas supply must be shut off at the cylinder valve or the cylinder must be removed
from the appliance until the leak(s) is corrected.