Desa (V)T32EN-A Series, (V)T32EP-A Series Outdoor Fireplace User Manual


 
www.desatech.com
116647-01B6
PRE-INSTALLATION
PREPARATION
Continued
NOTICE: This replace is in-
tended for use as supplemental
heat. Use this replace along
with your primary heating sys-
tem. Do not install this replace
as your primary heat source.
If you have a central heating
system, you may run system’s
circulating blower while using
replace. This will help circulate
the heat throughout the house.
In the event of a power outage,
you can use this replace as a
heat source.
FRAMING AND FINISHING
Figure 4 shows typical framing of this replace.
Figure 5 shows framing for corner installation. All
minimum clearances must be met.
For available accessories for this replace, see
Accessories on page 33. If you are using a separate
combustible mantel piece, refer to Figure 6 for
proper installation height. You can install noncom-
bustible mantels at any height above the replace.
Note: Noncombustible mantels may discolor!
Figure 4 - Framing Clearances for
Installation Against an Exterior Wall
32
3
/8"
34
5
/8"
17" (Horiz. Vent)
20" (Vert. Vent)
Figure 5 - Framing Clearances for Corner
Installation
A
B
E
F
G
H
D
C
Nailing Tabs
28
1
/2"
13
5
/
8
"
39
3
/8"
10
3
/8"
9
7
/8"
34
3
/8"
34
5
/8"
54
1
/8"
Nailing
Tabs
C
B
A
D
E
F
G
Top of Louver Opening
3
2
1
4
5
6
7
Wall
Figure 6 - Clearances for Combustible
Mantels
Ref.
Mantel
Depth Ref.
Mantel from Top of
Louver Opening
1 14" A 16"
2 12" B 14"
3 10" C 12"
4 8" D 10"
5 6" E 8"
6 4" F 6"
7 2" G 4"