Desa (V)T32EN-A Series, (V)T32EP-A Series Outdoor Fireplace User Manual


 
www.desatech.com
116647-01B22
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 33).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas replace or opening main gas
valve located on or near gas meter for natural
gas replace or using compressed air.
3. Check all joints from propane/LP supply tank
for propane/LP or gas meter for natural gas to
equipment shutoff valve (see Figure 34 or Figure
35). Apply noncorrosive leak detection uid to
all joints. Bubbles forming show a leak. Correct
all leaks at once.
FIREPLACE
INSTALLATION
Continued
Open
Closed
Equipment
Shutoff
Valve
Figure 33 - Equipment Shutoff Valve
PRESSURE TESTING FIREPLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 33).
2. Open propane/LP supply tank valve for
propane/LP fireplace or main gas valve
located on or near gas meter for natural gas
replace.
3. Make sure control knob of replace is in the
OFF position.
4. Check all joints from equipment shutoff valve
to gas valve (see Figure 34 or Figure 35).
Apply noncorrosive leak detection uid to all
joints. Bubbles forming show a leak. Correct
all leaks at once.
5. Light replace (see Operating Fireplace, page
23). Check all other internal joints for leaks.
6. Turn off replace (see To Turn Off Gas to Appli-
ance, page 24).
REMOVING/REPLACING GLASS
DOOR
CAUTION: Do not operate
this replace with a broken glass
door panel or without the glass
door panel securely in place.
For replacement part informa-
tion see Replacement Parts,
page 32.
CAUTION: Wear gloves and
safety glasses while handling or
removing broken glass. Do not re-
move if glass is hot. Keep children
and pets away from glass.
WARNING: If replace has
been running, turn off and un-
plug replace. Let cool before re-
moving glass door or louvers.
Removing Louver Panels
Remove the top and bottom louver panels by si-
multaneously pulling both top end spring latches
towards the center of the appliance until they are
disengaged from the locating holes (see Figure 36,
page 23). Repeat for bottom spring latches and pull
the louvers outward. To install or replace items
removed, simply reverse the procedures above.
Figure 34 - Checking Gas Joints for
Propane/LP Gas Fireplace
Propane/LP
Supply Tank
Gas Valve
Equipment
Shutoff Valve
Figure 35 - Checking Gas Joints for
Natural Gas Fireplace
Gas
Meter
Gas Valve
Equipment
Shutoff
Valve