Desa (V)T32EN-A Series, (V)T32EP-A Series Outdoor Fireplace User Manual


 
www.desatech.com
116647-01B32
SPECIFICATIONS
(V)T32EN(R)-A
Rating: 12/18,000Btu/Hr
Type Gas: Natural Gas Only
Ignition: Piezo
Manifold Pressure: 3.5" W.C.
Minimum Inlet Gas Pressure (in. of water): 5.5"
Dimensions (H x W x D) (Firebox only - Does
not include nailing flanges or standoffs):
32
1
/
4
" x 34
1
/
2
" x 16
5
/
8
"
Fireplace Weight*: Fireplace - 80 lb
Shipping Weight*: 83 lb
(V)T32EP(R)-A
Rating: 11/17,000Btu/Hr
Type Gas: Propane/LP Gas Only
Ignition: Piezo
Manifold Pressure: 10" W.C.
Minimum Inlet Gas Pressure (in. of water): 11"
Dimensions (H x W x D) (Firebox only - Does
not include nailing flanges or standoffs):
32
1
/
4
" x 34
1
/
2
" x 16
5
/
8
"
Fireplace Weight*: Fireplace - 80 lb
Shipping Weight*: 83 lb
*For refractory lined models add 45 lb
REPLACEMENT PARTS
Note: Use only original replacement parts. This
will protect your warranty coverage for parts
replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized retailers of this product. If
they can not supply original replacement part(s),
call DESA’s Technical Service Department at
1-866-672-6040.
When calling DESA, have ready
• your name
• your address
• model and serial numbers of your replace
• how replace was malfunctioning
• type of gas used (propane/LP or natural
gas)
• purchase date
Usually, we will ask you to return the part to the
factory.
PARTS NOT UNDER WARRANTY
Contact authorized retailers of this product. If
they can not supply original replacement part(s),
call DESA at 1-866-672-6040 for referral infor-
mation.
When calling DESA, have ready
model number of your replace
the replacement part number
SERVICE HINTS
When Gas Pressure Is Too Low
pilot will not stay lit
burners will have delayed ignition
replace will not produce specied heat
propane/LP gas supply might be low (propane/
LP units only)
You may feel your gas pressure is too low. If so,
contact your local gas supplier.
TECHNICAL SERVICE
You may have further questions about installation,
operation or troubleshooting. If so, contact DESA’s
Technical Service Department at 1-866-672-6040.
When calling, please have your model and serial
numbers of your heater ready.
You can also visit DESA’s technical service web site at
www.desatech.com.