Cooker King Cooker King Kooker OUTDOOR COOKER Gas Grill User Manual


 
CONNECTION INSTRUCTIONS
1. Check that your 20 lb. LP gas cylinder is not over-filled. The maximum weight of a properly filled
cylinder is approximately 38 lbs.
2. Verify that the cylinder valve has the proper connection for a P.O.L. appliance fitting.
3. Attach the regulator to the cylinder by the lefthand threaded P.O.L. fitting. The P.O.L. nut must be
wrench tightened with the regulator positioned upright.
LEAK TEST
4. Before lighting the appliance, a thorough leak test must be satisfactorily completed using a
non-ammonia soapy water solution (50% non-ammonia soap and 50% water). This is to be
applied with a small brush to all gas joints after the cylinder valve is opened (no more than 1/2
turn). If bubbles are seen, indicating a leak, turn off the cylinder and tighten the leaking
connection until a further leak test shows no leaks.
If a repair cannot be made, call your local dealer or Metal Fusion, Inc., (800) 783-3885, for
assistance.
DO NOT USE UNTIL REPAIRS ARE MADE
5. Before lighting the cooker, check that the venturi tube is free of obstruction and is properly located
over the orifice. Both situations must be corrected, if necessary, before lighting to prevent
flashback.
20
SECTION II
USE AND CARE