Weber E210 Gas Grill User Manual


 
26 WWW.WEBER.COM
®
ROUTINE MAINTENANCE
IGNITER MODULE WIRE CHART (E210 / E310 / SP310)
1
2
1
2
3
4
3
4
BURNER 1 IGNITER BUTTON
Black Terminal (1) Black Terminal (3)
Yellow Terminal (2) Black Terminal (4)
MAINTAINING THE ELECTRONIC
CROSSOVER
®
IGNITION SYSTEM
The igniter module supplies power to the electronic
Crossover
®
ignition system and the side burner with
one igniter button. Whether you are performing routine
maintenance or a troubleshooting check on the ignition
system, read the following to keep your ignition system
working properly.
If the electronic Crossover
®
ignition system fails to ignite,
you'll need to pinpoint where the problem is occurring:
with the gas ow or with the electronic ignition system.
Begin by attempting to match light your burners. Refer
to “MAIN BURNER IGNITION - Lighting with a Match.”
If match lighting is successful, the problem lies in the
ignition system.
• VerifythattheAAbattery(alkalineonly)isingood
condition and is installed correctly (1). Some batteries
have a plastic protective wrap around them. This
plastic must be removed before installing battery. Do
not confuse this plastic with the battery label.
• Makesuretheigniterwiresareproperlyattachedto
the igniter module. Refer to the “IGNITER MODULE
WIRE GUIDE” chart on this page.
• Makesuretheceramicigniterassemblyisfully
inserted into burner tube igniter channel (2). If properly
positioned, you will hear a snap (3).
• Makesuretheelectronicigniterbuttonisworkingby
listening for clicking and looking for sparks at burner.
If the electronic Crossover
®
ignition system still fails
to ignite, contact the Customer Service Representative
in your area using the contact information on our web
site. Log onto www.weber.com
®
.
1
2
3