Weber E210 Gas Grill User Manual


 
20 WWW.WEBER.COM
®
ANNUAL MAINTENANCE
9
8
7
5
43
6
1
2
BURNER TUBE CLEANING
OR REPLACEMENT
Conrm that Grill Is Off
A) Turn gas supply off at source and disconnect gas
tting.
B) Check that all burner control knobs are in the off
( )position. Check by pushing control knobs in and
turning them clockwise until they stop. If they do not
turn, they are already off. If they do turn, continue
turning them clockwise until they stop; then they are
off. If your grill has a side burner, make sure the side
burner control knob is turned off.
Remove Control Panel
You will need: A Phillips screwdriver.
A) Open cabinet door. Remove igniter wires from wire
clips on the inside left panel (1). Disconnect wires
from igniter module inside the cabinet(2).
NOTE: Do not disconnect by pulling on wires; pull
from terminals at ends of wires.
B) Remove cookbox components(3).
C) Remove control knobs(4).
D) Remove screws from the front of the control panel
with a Phillips screwdriver(5).
E) Carefully lift control panel up and then pull forward and
away from cookbox(6).
Remove Manifold
Youwillneed:APhillipsscrewdriver,two7/16"wrenches.
A) With the Phillips screwdriver, remove two screws
and two washers attaching manifold to front cross
brace(7).
B) Usingtwo7/16"wrenches,removetwoboltsandtwo
nuts attaching manifold to cookbox (8). Pull manifold
forward and away from burner tubes (9). Manifold will
remain attached to corrugated gas line(s). Be careful
not to let manifold scratch frame or door or kink the
attached corrugated gas line(s).