Monessen Hearth BWBC400I Fire Pit User Manual


 
28
GLASS DOOR INSTALLATION AND FAN ACCESSORY
F
AN ASSEMBLY
The model BWBC500 and BWBC500I Fireplaces may be equipped with a accessory fan Model FA2. If the
fireplace is to be equipped with this accessory at anytime, the JB1 junction box assembly must be installed on
the fireplace as shown by Figures 32 and 33 during the installation of the fireplace. Unless the JB1 junction
box is installed at this time, wall finishing materials must be removed to gain access to the side of the fireplace
to install the JB1 junction box at a later date. Complete Installation and Operation Instructions for the FA2 Fan
are included in the package with this accessory.
Note: A rectangular switch knockout is provided on the lower right hand face of the fireplace.
GLASS DOOR INSTALLATION
This fireplace has been tested and listed for use with optional Model GD42P or GD42PB glass doors. For
installation of the Models GD42P or GD42PB glass doors, see the instructions provided with the doors.
NOTE: THE THREE PRONG RECEPTACLE
NOTE: THE THREE PRONG RECEPTACLE
AND ITS COVER MUST BE EXPOSED AND
AND ITS COVER MUST BE EXPOSED AND
THE COVER PLATE MUST BE REMOVABLE
THE COVER PLATE MUST BE REMOVABLE
FOR INSPECTION OF WIRING CONNECTION
FOR INSPECTION OF WIRING CONNECTION
ONCE THE FIREPLACE IS INSTALLED.
ONCE THE FIREPLACE IS INSTALLED.
FASTEN MODEL JBI JUNCTION
FASTEN MODEL JBI JUNCTION
BOX TO THE SIDE OF THE 
BOX TO THE SIDE OF THE 
FIREPLACE WITH THE TWO
FIREPLACE WITH THE TWO
SHEET METAL SCREWS REMOVED
SHEET METAL SCREWS REMOVED
FROM JUNCTION BOX
FROM JUNCTION BOX
OPENING COVER.
OPENING COVER.
JUNCTION BOX
JUNCTION BOX
OF FIREPLACE
OF FIREPLACE
TO FUSE OR
TO FUSE OR
CIRCIUT BREAKER
CIRCIUT BREAKER
GROUND
GROUND
WHITE
WHITE
BLACK
BLACK
NOTE: THE JB1 JUNCTION BOX SHOULD BE INSTALLED AND THE RECEPTACLE WIRED TO THE E
NOTE: THE JB1 JUNCTION BOX SHOULD BE INSTALLED AND THE RECEPTACLE WIRED TO THE E
LECTRICAL SYSTEM OF
LECTRICAL SYSTEM OF
THE STRUCTURE AT THE TIME OF INSTALLATION OF THE FIREPLACE OF THE FA
THE STRUCTURE AT THE TIME OF INSTALLATION OF THE FIREPLACE OF THE FA
2 FAN ASSEMBLY IS TO BE USED.
2 FAN ASSEMBLY IS TO BE USED.
SWITCH
SWITCH
(SPST)
(SPST)
CORDSET
CORDSET
120V, 60HZ
120V, 60HZ
(FAN ASSEMBLIES)
(FAN ASSEMBLIES)
M2
M2M1
GAS APPLIANCE
GAS APPLIANCE
OPENING COVER
OPENING COVER
JUNCTION BOX
JUNCTION BOX
OPENING COVER
OPENING COVER
MODEL JBI JUNCTION BOX INSTALLATION
MODEL JBI JUNCTION BOX INSTALLATION
REMOVE JUNCTION BOX
REMOVE JUNCTION BOX
COVER FROM FIREPLACE.
COVER FROM FIREPLACE.
BELK LOUVER KIT
BELK LOUVER KIT
FIGURE 32
FIGURE 33
53D9032. Rev 1 03/03